CGI Corrugated Curving sheet can be pre-curved by Stratco into a variety of forms to produce concave or convex curves, bullnose roofing, or barrel vaulting (a complete half circle), in either concave or convex arrangements. This style of roofing can be ordered to suit your exact requirements. Whether you want to install it yourself or require assistance, we are here to help. Contact us for pricing and further details today.

Curved Creations

Custom Made For Your Project

Pre-Curved sheeting allows for complex curved designs that complement both traditional homes and modern architecture. Factory pre-curved to your requirements in high quality CGI Curving sheet by Stratco in a variety of forms including concave, convex, bullnose and barrel vault designs.

Cladding Roofing Sheeting Walling CGI Pre Curving Concave
Cladding Roofing Sheeting Walling CGI Pre Curving Convex
Cladding Roofing Sheeting Walling CGI Pre Curving Bullnose
Cladding Roofing Sheeting Walling CGI Pre Curving Barrel Vault

Available Colours:

Curved Roofing Accessories

Finish your curving project with accessories manufactured by Stratco such as curved flashings to match your sheeting radius and curved hip bars for bracing the hip joint.

Bullnose Verandah Components

Bullnose Verandah With Internal Framework

Cladding Roofing Sheeting Walling CGI Pre Curving Components With Internal Framework

Bullnose Verandah Without Internal Framework

Cladding Roofing Sheeting Walling CGI Pre Curving Components Without Internal Framework

Cladding Roofing Sheeting Walling CGI Pre Curving Components 08

1. Curved Cladding

Cladding Roofing Sheeting Walling CGI Pre Curving Components 04

2. Hip Bracing

Cladding Roofing Sheeting Walling CGI Pre Curving Components 05

3. Hockey Sticks

Cladding Roofing Sheeting Walling CGI Pre Curving Components 06

4. Curved Barge

Cladding Roofing Sheeting Walling CGI Pre Curving Components 07

5. Curved Hip

Cladding Roofing Sheeting Walling CGI Pre Curving Components 03

6. Straight Ridge

Cladding Roofing Sheeting Walling CGI Pre Curving Components 09

7. 33mm Back Channel

Cladding Roofing Sheeting Walling CGI Pre Curving Components 10

8. 33mm BIP Foam

Cladding Roofing Sheeting Walling CGI Pre Curving Components 11

9. Curved Apron

Cladding Roofing Sheeting Walling CGI Pre Curving Components 12

10. Sheet Fixing Flashing (For Probeam)

Preferred Ordering Method

Note: Curving of CGI will produce a minimum straight section at the end of the curve of at least 60mm. Stratco takes no responsibility for deformation that may occur from smaller radii. Contact Stratco for further curving specifications.

Supply of the profile template:

The template must be provided at time of ordering.
No responsibility will be accepted for sheets curved from drawings.

Ordering Information

A - Distance from fascia front to wall.
B - Fascia height to wall attachment distance.
C - Required concave dip or convex rise.
D - Pitch angle from wall.
R - Radius required.

Additional Information Required

  • Number of sheets required.
  • Sheet lengths required.
  • Type of curve.
  • Direction of laying.
  • Type of material.
  • Colour topside or underside?

Bullnose Forming

Recommended minimum radius 450mm.
Maximum sheet length 6000mm.

Cladding Roofing Sheeting Walling CGI Pre Curving Bullnose Order 1
Cladding Roofing Sheeting Walling CGI Pre Curving Bullnose Order 2

Concave/Convex Forming

Recommended minimum radius 450mm.
Maximum sheet length 6000mm.

Cladding Roofing Sheeting Walling CGI Pre Curving Concave Order 1
Cladding Roofing Sheeting Walling CGI Pre Curving Concave Order 2
Cladding Roofing Sheeting Walling CGI Pre Curving Convex Order 1
Cladding Roofing Sheeting Walling CGI Pre Curving Convex Order 2

Barrel Vaulting

Recommended minimum radius 450mm.
Maximum sheet length 10,000mm.

Cladding Roofing Sheeting Walling CGI Pre Curving Barrel Vault Order 1
Cladding Roofing Sheeting Walling CGI Pre Curving Barrel Vault Order 2

Spans

Maximum Recommended Spans (mm)
BMT Application Internal Span End Span
0.60 Roofing 1800 1600
0.60 Walling 3000 2900

Minimum recommended curving radius is 450mm. Sheet coverage is 762mm.

Sheet Length and Curving Calculation Procedure

Bullnose Verandahs

Step 1

Dimensions Required:
Width of Verandah - wall to outside face of fascia beam (X)
Height - top of fascia beam to underside of verandah sheet (Y)
Plot these lines to scale on graph paper.

Step 2

Draw the straight section of sheet (A) at the required fall.
Note: Corrugated iron is not recommended for a pitch of less than 5 degrees.

Step 3

Determine the radius of curvature:
Note: The recommended minimum radius for CGI curving is 450mm.
Stratco takes no responsibility for deformation that may occur from smaller radii.

Cladding Roofing Sheeting Walling CGI Pre Curving Diagram

Step 4

Set a compass to the radius of curvature and scribe arcs from both ends of line (A).
Connect arc tangents to form parallel line (B).
Set the compass point to the top front corner of the fascia Beam (C) and scribe an arc to intersect line B.
From this intersection (D) set the compass point and scribe an arc from line (A) to a point 50mm past the fascia (E).

Step 5

Calculating the roof sheet length:

  • Extend a perpendicular line from point (D) to intersect line (A)
  • Draw a line from point (D) to point (E)
  • Measure the resulting angle (F°)
  • Measure the length of straight sheet
  • Calculate the length of curvature using the following formula:

2πr x angle (F°)
360

  • Add the length of straight sheet to the curve length to determine the total sheet length

Cladding Roofing Sheeting Walling CGI Pre Curving Diagram


Concave and Convex Verandahs

Step 1

Dimensions Required:
Width of Verandah - wall to outside face of fascia beam (X)
Height - top of fascia beam to underside of verandah sheet (Y)
Plot these lines to scale on graph paper.

Step 2

Draw a straight line (A) between the wall and fascia beam as shown in below.
Locate the mid-point of line (A) and plot a perpendicular line (B) from this point.
Determine the required dip and plot the point of intersection (C) on line (B).

Cladding Roofing Sheeting Walling CGI Pre Curving Diagram

Step 3

Using a flexible scale ruler, join the top and bottom of line (A) through point (C).
Read the required sheet length from the scale ruler, allowing an additional 50mm past the fascia.
If required, adjust the dip to effectively suit the fall into the gutter.

Note: A minimum dip of 50mm is recommended for aesthetic reasons.
For convex verandahs repeat Step 1 to 3, however, plot the intersection point (C) on the opposite side of line (A) at the convex rise.

Cladding Roofing Sheeting Walling CGI Pre Curving Diagram

Preferred Ordering Method

Note: Curving of CGI will produce a minimum straight section at the end of the curve of at least 60mm.
Stratco takes no responsibility for deformation that may occur from smaller radii.
Please contact Stratco for further curving specifications.

Supply of the profile template:
The template must be provided at time of ordering.
No responsibility will be accepted for sheets curved from drawings.

Ordering Information

A - Distance from fascia front to wall.
B - fascia height to wall attachment distance.
C - Required concave dip or convex rise.
D - Pitch angle from wall.
R - Radius required.

Additional Information Required

  • Number of sheets required.
  • Sheet lengths required.
  • Type of curve.
  • Direction of laying.
  • Type of material.
  • Colour topside or underside?

Change Location