has been added to your cart
View Cart

Tuffloor® Flooring

Stratco

SKU: Tuffloor-Flooring

Tuffloor Steel Flooring is ideal for domestic housing and house extensions. It supports a wide range of floor cladding and is a strong, long lasting, lightweight alternative to timber framing. This style of flooring can be ordered to suit your requirements. Whether you want to install it yourself or require assistance, we are here to help. Contact us for pricing and further details today.

Tuffloor® Steel Flooring

Strong, lightweight, durable and easy to install steel flooring system

Tuffloor is a steel floor framing system designed for strength and ease of installation, and is an easy and economical alternative to timber subfloors. The system is ideal for domestic house construction and extensions, and suits cladding with either tongue and grooved strip flooring, or a wide range of particleboard, and composite products.

It is suitable for commercial and light industrial applications, although you should refer these applications to Stratco to determine allowable spans for these load conditions. Tuffloor is pre-cut to length, eliminating on-site cutting, saving you time and effort.

Suited To Your Project

It is particularly suited for use with reactive soils, and sloping sites, and can be installed in remote locations without the need for cartage of extensive installation infrastructure. Offering economical spanning performance, Stratco Tuffloor is adaptable to a variety of building designs and construction methods.

Economical

All major structural components are made from high tensile steel providing strength and impact resistance. The efficient strength to weight ratio of high tensile steel minimizes the weight of materials needed to be transported to site, saving money in remote locations. With the increased load bearing capacity of the Tuffloor system, smaller sections can be used, contributing to cost efficiency. When this is combined with in-line construction, the total height of the building can be reduced, further saving brick and cladding costs. Keeping project costs under control is always a challenge on any building project and choosing Tuffloor for your project makes a lot of sense.

Versatile

235mm sections allow for 115mm pipe penetrations and toilet bends under the floor, and standard joist spacings compatible with a large variety of flooring materials.

Long Life

The galvanised coating offers long term protection against corrosion. As the subfloor is made from steel it is not subject to twisting or warping. Other benefits include termite protection, mould resistance and elimination of wood rot.

Components

Steel Framing Floor Flooring Frame Component 01

Joist

Steel Framing Floor Flooring Frame Component 02

Bearer

Steel Framing Floor Flooring Frame Component 03

Joist Angle Bracket

Steel Framing Floor Flooring Frame Component 04

Bearer Angle Bracket

Steel Framing Floor Flooring Frame Component 05

Web Strengthening Bracket

Steel Framing Floor Flooring Frame Component 06

Four Hole Column Cap

Steel Framing Floor Flooring Frame Component 07

Two Hole Column Cap

Steel Framing Floor Flooring Frame Component 08

Corner Column Cap

Steel Framing Floor Flooring Frame Component 09

Base Plate

Steel Framing Floor Flooring Frame Component 10

Bracing

Steel Framing Floor Flooring Frame Component 11

Fixings

Design Information

Stratco Tuffloor flooring conforms with the following Australian standards:

  • AS 4100:1998 Steel Structures.
  • AS/NZS 4600:1996 Cold-formed Steel Structures.
  • AS/NZS 1170:2002 Structural Design Actions.
  • AS 3623:1993 Domestic Metal Framing.

The following design loads are used in the determination of the span tables:

Floor Loads

  • 2.0 kPa, live load
  • 0.6 kPa, dead load
  • 1.8 kN, concentrated load

Roof Loads

  • 0.9 kPa tiled roof dead load
  • 0.3 kPa steel roof dead load
  • 0.25 kPa live load

Wall Loads

  • 0.8 kN/m dead load

Design Criteria

The Roof Load Width is the effective width of roof that the bearer is supporting. The diagram below shows a simplified method for determining the Roof Load Width.

Steel Framing Floor Flooring Frame Design Criteria

Section Properties

Section Properties
Joist Section Depth mm Width mm Lip mm Thickness mm Mass kg/m
Steel Framing Floor Flooring Frame Joist Section FJO18212 182 51 14 1.2 2.79
FJO18215 182 51 14 1.5 3.54
FJO18219 182 51 15 1.9 4.46
FJO18224 182 51 16 2.4 5.62
FJO23515 235 62 14 1.5 4.50
FJO23519 235 64 15 1.9 5.68
FJO23524 235 64 16 2.4 7.15
Bearer Section Depth mm Width mm Lip mm Thickness mm Mass Kg/m
Steel Framing Floor Flooring Frame Bearer Section FBE18219 187 58 0 1.9 4.46
FBE18224 187 58 0 2.4 5.62
FBE23519 240 72 0 1.9 5.68
FBE23524 240 72 0 2.4 7.15

All sections are galvanised to Z350 specifications and are rolled out of high tensile material with a minimum yield strength of 450MPa.

Joists

Joist members are to be simply supported between bearers and should be used with bearers of the same depth. Spans for joist spacings less than 450mm should be based on 450mm.

Steel Framing Floor Flooring Frame Joists

Joists Not Supporting a Roof Load
Maximum Joist Span mm - Not Supporting Load Bearing Walls
Joist Joist Spacing
450mm 600mm
FJO18212 3300 2750
FJO18215 3750 3600
FJO18219 4350 4000
FJO18224 4550 4250
FJO23515 4700 4400
FJO23519 5400 5200
FJO23524 5500 5400

Interpolation may be used for intermediate values.

Joists Supporting a Roof Load
Maximum Joist Span mm - Supporting Load Bearing Walls
Joist Steel Roof Tiled Roof
FJO18212 2250 1850
FJO18215 2450 2100
FJO18219 2650 2150
FJO18224 2900 2400
FJO23515 3000 2650
FJO23519 3350 2750
FJO23524 3650 3000

Max 450mm joist spacing, where load bearing walls are not parallel to joists.
Note: These span tables must be read in conjunction with the Stratco Tuffloor Design Guide.

Bearers

Bearers are used to transfer the loads from the floor and roof into the floor support system. Only bearers are permitted to be attached to the floor support system.

Bearers Not Supporting a Roof Load
Joist Span
mm
Max Internal and Perimeter Bearer Span mm
Not supporting load bearing walls or fixed to joists supporting load bearing walls
FBE18219 FBE18224 FBE23519 FBE23524
0 4350 4550 5400 5500
1200 3380 3650 4250 4650
1800 2950 3200 3700 4050
2400 2650 2700 3350 3700
3000 2450 2550 3100 3400
3600 2300 2400 2950 3200
4200 2200 2300 2800 3050
4800 2100 2200 2650 2900
5400 - - 2550 2800
6000 - - 2450 2700

Interpolation may be used for intermediate values.

Bearers Supporting a Steel Roof
Maximum Internal and Perimeter Bearer Span mm
Supporting load bearing walls or fixed to joists supporting load bearing walls
Joist Span
mm
FBE18224 Roof Load Width mm FBE23524 Roof Load Width mm
4000 6000 8000 4000 6000 8000
0 3400 3100 2900 4300 3900 3650
2400 2900 2800 2650 3700 3550 3350
3000 2700 2700 2600 3400 3400 3300
3600 2550 2550 2550 3200 3200 3200
4200 2400 2400 2400 3050 3050 3050
4800 2300 2300 2300 2900 2900 2900
5400 - - - 2800 2800 2800
6000 - - - 2700 2700 2700

Interpolation may be used for intermediate values.

Bearers Supporting a Tiled Roof
Maximum Internal and Perimeter Bearer Span mm
Supporting load bearing walls or fixed to joists supporting load bearing walls
Joist Span
mm
FBE18224 Roof Load Width mm FBE23524 Roof Load Width mm
4000 6000 8000 4000 6000 8000
0 2900 2600 2400 3650 3250 3000
2400 2650 2450 2250 3350 3100 2850
3000 2600 2400 2250 3300 3050 2850
3600 2550 2350 2200 3200 3000 2800
4200 2400 2350 2200 3050 2950 2700
4800 2300 2300 2150 2900 2850 2650
5400 - - - 2800 2750 2600
6000 - - - 2700 2700 2500

Interpolation may be used for intermediate values.
Note: These spans must be used in conjunction with the 'Stratco Tuffloor Design Guide'.

Connections

Joists - Joists should be fixed to the bearers using one of the methods shown below.

Steel Framing Floor Flooring Frame Connection Joist 01
Steel Framing Floor Flooring Frame Connection Joist 02
Steel Framing Floor Flooring Frame Connection Joist 03
Steel Framing Floor Flooring Frame Connection Joist 04

Bearers - Stratco can supply column caps and base plates to suit 65, 75 and 100mm SHS steel columns.

Steel Framing Floor Flooring Frame Connection Bearer 01
Steel Framing Floor Flooring Frame Connection Bearer 02
Steel Framing Floor Flooring Frame Connection Bearer 03
Steel Framing Floor Flooring Frame Connection Bearer 04
Steel Framing Floor Flooring Frame Connection Bearer 05
Steel Framing Floor Flooring Frame Connection Bearer 06

For more information on Tuffloor design specifications and connection details, please refer to the Stratco Tuffloor installation and design guides.

Change Location

Please enter a valid postcode